<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-17 10-24-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 53 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 16 kHz 10660 0,0375
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,1 dBr 3,16 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 16 kHz MIN: 11 kHz % above 76 kHz: 0,0375 Acquired: 2025/08/17 10.23.23 Total samples: 10660 Equivalent time: 0:08:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,0 dBr MIN: 0,1 dBr AVE: 3,16 dBr % above 12,2 dBr: 0,0 Last value: 2,2 dBr (2025/08/17 10.23.22) 10.10 10.12 10.14 10.16 10.18 10.20 10.22 0 2 4 6 Pm [dBr]